News & Events
Republic Floor Pure SPC/SPC MAX 100 % Waterproof Flooring Warranty & Care Instructions
Product Inspections
Inspection of all flooring materials must be done before installation. Materials with visible defects are not covered under warranties once they are installed.
Our Pure SPC floors are manufactured in accordance with accepted industry standards, which permit defect tolerance not to exceed 2%.
Sub-floor must be flat, dry, smooth, level and free from residues and structurally sound. A level slope is a foundation that is less from 5mm over 2 meters or ¼” over 6 feet.
Concrete subfloor must have moisture testing and a layer of Visqueen type (6mil semi clear plastic sheeting) moisture barrier laid prior to flooring installation. Documents must be kept of all test results for warranty purposes.
Flooring may be installed over existing floor if existing floor meets criteria of flat, smooth, dry,
and level. For ceramic tile, grout lines need to be filled in with leveling material prior to installing
flooring.
Check that the doors can still open and close after the Pure SPC flooring is installed.
Pure SPC floors can be installed over of a multitude of in-floor heating systems, provided that
instructions from the supplier of the in-floor heating system are followed.
The temperature of the sub-floor or the heat radiating from electric heating mats should not
exceed 84 degrees Fahrenheit (29 degrees Celsius)
Pure SPC flooring must be installed indoors
Pure SPC flooring should not be exposed to temperatures above 140° F (60° C) or below 32° F (0° C)
Expansion space should be left around the perimeter. Typically expansion is equal to the thickness of the product installed. You can install on grade, below grade or above.
Republic Floor requires 3/8” expansion for every 20 feet in length or width. A T-molding is required for greater than 40 feet in length or width.
A ¼” expansion space must also be for undercut jambs and casing.
Start in a corner and lay first row with tongue sides toward walls. Proper expansion space can be achieved by pulling floor away from wall once first three rows have been installed.
Hold the next board against the first board at approximately 45 degree angle and lay flat on floor. Continue in this manner for the entire first row.
Cut end board in first row to correct length and start second row with left over piece (if possible).
End joints must be staggered by at least 8” for a natural random appearance. Butt seam must be placed in each row regardless of width. Hold boards approximately 45 degree angles to board in front. Press forward to engage joint and lay flat on floor.
When three rows have been laid, pull floor away from starting wall until there is proper amount of expansion space. Place shims between floor and wall to maintain this space.
You can proceed until the entire floor is finished. Install quarter rounds or wall base. Kitchen island and cabinetry installations should be done before flooring is installed with the flooring next to the installed cabinetry/island.
Warranty
Pure SPC flooring carries a limited 25 year residential warranty and a limited 10 year commercial warranty for wear to the finish under proper usage and maintenance conditions. Pure SPC flooring is guaranteed to be 100% waterproof but spills should be cleaned in a timely manner to prevent the possibility of mold or mildew growth.
The guarantee applies only to the original purchaser and proof of purchase is required for all claims. The guarantee is for replacement or refund of the Pure SPC material only, not for any labor. Claims for wear must show a minimum dime size area. This guarantee is pro-rated based on the amount of time the Pure SPC floor has been installed. A percentage would be replaced depending on the length of time since the Pure SPC floor was installed. Defect of goods must be proven by inspection procedures deemed proper by the Manufacturer. Warranty is conditioned upon Manufacturers receipt of notice in writing from the buyer of the alleged defect prior to expiration of the warranty period and evidence that the products were properly installed and not
subject to any of the exclusions described below.
Exclusions
Any visible defects noted after installation
The guarantee does not cover chipping (material will chip if sharp objects are dropped on
it), or bridging (which is caused by insufficient expansion spacing). We will not consider
any claims for these problems.
Consequential or incidental damages, such as any loss, expense or damages other than to
the flooring itself that may result from a defect in the flooring
Improper installation including, but not limited to, installation by non-licensed
individual(s)
Additional underlayment when pad is attached
Failure to document results of moisture test on concrete subfloor.
Failure to use moisture barrier such as Visqueen on concrete subfloor
Improper maintenance or inadequate care, including, but not limited to, mold or mildew
growth as a result of excessive moisture accumulation
Use of steam mops or hard bristle vacuums
Accidents, abuse, or misuse
Building settling or uneven sub-floor
Wheelchairs, office chairs, or any heavy mobility equipment
Heavy furniture causing pinch points
High heel shoes with pointed heels
Damages caused by furniture without felt pads or protective covers
Damages caused by sharp objects making contact with the floor
Damage caused by excessive sunlight
Damages caused by liquids/food product stains
Damages caused by urine or other bodily fluids
GENERAL INFORMATION
Sub-Floor Preparation
Preparing the Room
Radiant Floor Heating
Installation Guidelines
WARRANTY INFORMATION
MAINTENANCE INFORMATION